Azure Problems |
Warning or Error |
100800 - 100899 |
Any Error or Warning |
Transient problems reading or writing to Azure table store will be logged as Warning. Transient read errors will automatically be retried. A final Error log message means there is a real problem connecting to Azure table storage. |
Gateway connectivity problems |
Warning or Error |
100901 - 100904, 100912, 100913, 100921, 100923, 100158, 100161, 100178, , 101313 |
Any Error or Warning |
Problems connecting to gateways. No active gateways in the Azure table. Connection to active gateway lost. |
Grain call timeouts |
Warning |
100157 |
Multiple Warnings logged in short space of time |
Grain-call timeout problems are generally caused by temporary network connectivity issues or silo restart / reboot problems. System should recover after a short time (depending on Liveness config settings) at which point Timeouts should clear. Ideally, monitoring for just the bulk log code 600157 variety of these warnings should be sufficient. |
Network Socket Problems |
Warning or Error |
101000 to 101999, 100307, 100015, 100016 |
Any Error or Warning |
Socket disconnects are logged as Warning messages. Problems opening sockets or during message transmission are logged as Errors. |
Bulk log message compaction |
Any |
500000 or higher |
Message summary based on bulk message threshold settings |
If multiple logs of the same log code occur within a designated time interval (the default is >5 within 1 minute) then additional log messages with that log code are suppressed and output as a “bulk” entry with log code equal to the original log code + 500000. So for example, multiple 100157 entries will show in the logs as 5 x 100157 + 1 x 600157 log entry per minute. |